Chapter 2 • Installing the indoor equipment
6
1031484-0001 Revision 2
Two DW4020 installation
methods
There two ways to install the DW4020.
• If an analog phone line is available, assemble and install the 
system using the instructions in Installing the system using a 
modem
 on page 11. Th
is method is preferred and is usually 
the one that will be used.
• If no analog phone line is available, you must configure the 
DW4020 through the serial port. Follow the instructions in 
Appendix C.
Summary of DW4020
installation process
DW4020 installation is a 10-step process.
1. Assemble the DW 4020 components.
2. Connect the DW4020 to the installer PC Ethernet and power 
up the DW4020. Use surge protectors.
3. Connect the installer PC via USB and run Websetup to 
establish operating parameters and commission.
4. Register the customer and select subscription options via 
Websetup.
5. Record site ID and assigned IP address(es) for the customer 
on the cover of the User Guide.
6. Transfer of parameter information to Gateway Host; Exit 
Websetup.
7. Assemble and install the satellite antenna. Run cables from 
the outdoor components to the indoor equipment. Clearly 
label the receive and transmit coaxial cable at the antenna, 
ground block, and indoor units connectors.
8. Complete pointing and ACP.
9. Disconnect installer PC and connect the Gateway to the 
receive modem with the USB cable. Connect the customer 
computer equipment to the Gateway via Ethernet cable. 
10. Verify customer operation, information recorded on User 
Guide cover, and receive and transmit cable labeling. 
Optional: assist in customer computer configuration.
Antenna installation
The DW4020 can be used with the HNS DW4000 74cm 
Two-Way antenna. The DW4020 can also be used in conjunction 
with 98cm, 1.2m, and 1.8m antennas. Refer to the manufacturer’s 
antenna installation manual for instructions on how to install the 
antenna. See the About section for a list of antenna installation 
manuals. Follow all safety procedures. Cable requirements are on 
page 4.