Graco 311163ZAC Bin Evacuation System Manual De Usuario

Descargar
Página de 64
Manual Control System
311163ZAC
17
Pressure Relief Procedure
1.
To turn off the pumps move pump switch to OFF.
2.
Shut off the air to the pumps by closing the 
bleed-type air shutoff valve on the pumps’ air supply 
line, or disconnect the air line.
3.
Open all system fluid drain valves that are down-
stream of the pumps.
Initial Startup
This procedure takes you through the settings, adjust-
ments, and other steps that must be completed before 
the system is ready for daily operation.
1.
Fill all the pumps packing nut/wet cups 1/3 full with a 
compatible lubricant if applicable. Refer to your 
pump manual for details. Do not use Graco Throat 
Seal Lubricant with a sanitary application.
2.
Turn on the air to the pneumatic control panel.
3.
Turn SEAL INFLATE to OFF.
4.
Open the air shutoff valves for the pneumatic con-
trols and pumps.
5.
Open the pneumatic control panel door. Check for 
air leaks.
6.
The equipment was tested with water. Flush the 
system before loading material. See page 28.
7.
Follow Loading the Bin procedure, page 18.
8.
Set the ram down air regulator to 30 psi (207 kPa, 
2.1 bar). Adjust as needed.
9.
Adjust the pump regulator as needed.
NOTE: Pump cavitation occurs when the pump cylinder 
does not fully load with material on the up stroke and an 
air pocket forms in the material after the pump change-
over. If pump cavitation occurs, increase the ram down 
air pressure.
10. Adjust the seal vacuum pump air regulator to 15 psi 
(103 kPa, 1.0 bar).
11. Deflate the seal.
12. Press the RAM UP button. If the ram does not raise, 
increase the ram up air regulator pressure.
13. Verify the seal is completely deflated after the ram 
plate exits the bin. If it is not, deflate the seal.
14. When adjustments are complete, close the pneu-
matic control panel door.
15. Follow Unloading the Bin procedure, page 18.
16. The system is now ready for standard operation. 
See page 17.
Setting Air Pressures
Each system function has an associated air pressure. 
Air pressure regulators are located on the pneumatic 
control panel. Set initial air pressures as shown in the 
table below. Make adjustments as needed during opera-
tion. See F
*A pressure relief regulator is required when a control 
system other than a Graco control panel is used.
Trapped air can cause the pump to cycle 
unexpectedly, which could result in serious injury 
from injection, splashing or moving parts. Relieve 
pressure when you stop pumping and before 
cleaning, checking, or servicing equipment.
When raising or lowering the ram plate, keep hands 
and body away from ram plate and bin lip.
Ref. 
Key
Function
Regulator Setting
psi (kPa, bar)
B*
SEAL INFLATE
7 (48, 0.5)
Max: 15 (103, 1.0)
H
RAM UP
30 (207, 2.1)
K
RAM DOWN
30 (207, 2.1)
E
PUMP
50 (345, 3.4)