Graco 3A0591U Ram Packages Manual De Usuario
Operation
18
3A0591U
Cleaning Procedure
NOTE: The following instructions are a basic procedure
for cleaning a sanitary ram.
for cleaning a sanitary ram.
•
Be sure to follow your national and state sanitary
standard codes and local regulations.
standard codes and local regulations.
•
Use appropriate cleaning and disinfecting agents, at
intervals appropriate for product processed.
intervals appropriate for product processed.
•
Follow cleaning product manufacturer’s instructions.
1.
Remove the pump from the fluid container. Operate
it to pump out as much fluid as possible.
it to pump out as much fluid as possible.
2.
Flush the system thoroughly with an appropriate
cleaning solution.
cleaning solution.
3.
Set the inflatable seal valve (BJ) to deflate.
4.
Set the director valve (BC) to UP to raise the ram
plate.
plate.
5.
If needed, use air assist (BG) to help lift the ram
plate.
plate.
6.
Raise the ram plate until it is completely out of the
drum. Remove the empty drum.
drum. Remove the empty drum.
7.
Disconnect inflatable seal supply air.
8.
Pull the inflatable seal down to remove. Clean and
sanitize the seal.
sanitize the seal.
NOTE: Discoloration of the inflatable seal is normal.
Replace the inflatable seal if the surface is compromised
due to excessive wear, tears, cuts, or gouges.
Replace the inflatable seal if the surface is compromised
due to excessive wear, tears, cuts, or gouges.
9.
Set the director valve to DOWN. Lower the ram
plate.
plate.
10. Follow the Pressure Relief Procedure, page 14.
11. Disconnect all remaining air and fluid hoses, and
remove air inlet and exhaust fittings.
12. Remove and clean the pump.
NOTE: The pump must be disassembled to thoroughly
clean it. See your separate pump manual for complete
flushing and cleaning procedures for a sanitary pump.
Any damaged rubber parts must be replaced as they
could harbor microorganisms that can contaminate the
fluid.
clean it. See your separate pump manual for complete
flushing and cleaning procedures for a sanitary pump.
Any damaged rubber parts must be replaced as they
could harbor microorganisms that can contaminate the
fluid.
13. Remove, clean, and sanitize the clamps (12, 13),
ram plate (5) and seal (8).
14. Remove the air motor cover. Open the control box
door. Wipe out any residual cleaning fluid or mois-
ture.
ture.
15. Clean external surfaces of all parts before
reassembly.