Graco GE-DS-242-POE Manual De Usuario

Descargar
Página de 210
 
Chapter 4: Web-Based Management 
GE-DS-242-PoE Managed Ethernet Switch User Manual 
115 
Misc Configuration 
In this page, you can change the default configuration for the 802.1x standard: 
Figure 4-68: 802.1x Misc Configuration interface 
 
 
This page includes the following fields: 
 
OBJECT 
DESCRIPTION 
Quiet Period: 
Used to define periods of time during which it will not attempt to 
acquire a supplicant. 
Default time is 60 seconds. 
TX Period: 
Set the period the port waits for retransmit next EAPOL PDU during an 
authentication session. 
Default value is 30 seconds. 
Supplicant Timeout: 
Set the period of time the switch waits for a supplicant response to an 
EAP request. 
Default value is 30 seconds. 
Server Timeout: 
Set the period of time the switch waits for a server response to an 
authentication request. 
Default value is 30 seconds. 
Max Requests: 
Set the number of authentication that must time-out before 
authentication fails and the authentication session ends. 
Default value is 2 times. 
Reauth period: 
Set the period of time which clients connected must be re-
authenticated. 
Default value is 3600 seconds.