Graco 3A2894F - ExactaBlend AGP Advanced Glazing Proportioner Manual De Usuario

Descargar
Página de 78
Accessories and Kits 
60
3A2894F
Accessories and Kits
Light Tower 24R824
Visual and audible indicator of machine status.
Low Level Sensors, 24R935
(S100 and P100 only)
Alerts the user when material drums are empty.
Calibration Check Assembly, 
24R777
Allows the user to watch the DM while performing the 
Calibration Check procedure. Kit is required for all 
Ultra-lite dispense valve applications.
Status
Description
Red - Solid
An error has occurred and 
requires maintenance.
Red and Green - Solid
Allows a dispense but notifies 
the user of an uncleared error 
(e.g. low level).
Green - Solid
Machine is ready to dispense
Green - Flashing
Machine is okay. Gel timer 
has expired.