Graco 332223B - Retro-Fit Kit for LL250 and LL200 Manual De Usuario
Instructions for LL250 Units
332223B
3
Instructions for LL250 Units
Fan Belt Removal
1. Turn off unit. Relieve pressure in paint striper and
remove paint hopper.
2. Locate belt shroud (A). Use 3/8 in. wrench to loosen
or remove four screws and remove shroud.
3. Before loosening belt assembly, mark location of
hydraulic reservoir against stationary base.
4. Use 9/16 in. wrench to loosen (but do not remove)
four bolts (B) that secure hydraulic reservoir system
to base plate.
to base plate.
5. Loosen two belt tensioning bolts (C) to take tension
off of belt. Loosen only until belt can be removed.
6. Remove belt (D) from fan pulley (E).
Replace Pulley
1. Remove original pulley and replace with new pulley.
Use 1/8 in Allen wrench to tighten two set screws.
NOTE: Make sure key is in place before installing
new pulley.
new pulley.
2. Align new fan pulley (E) with engine pulley.
ti19128a
A
ti20529a
ti19147a
B
B
ti19146a
C
ti20885a
D
E
ti20526a
ti20528a
E