STARTUP SEqUENCE OF EVENTS
After the stove is plugged in the wall receptacle, the controller prompts the operator for commands. The parlor stove 
will start, stop and continue operation at the preset temperature. 
TRI-X STEP 1.  Select fuel type by pressing the MODE key.
TRI-X STEP 2.  Set stove heat cycle by pressing the AUX 1 key.
TRI-X STEP 3.  Start the MF3500 Parlor Stove by pressing the ON key.
COMPONENT
OPERATION START
OPERATION END
Exhaust Blower
Starts Immediately.
Will continue until shutdown. Shutdown will 
occur when the operating temperature is 
below 90º.
Feed Auger
Auger automatically starts when ON key is 
pushed.
The auger will continue at the feed rate 
specified by the HEAT SETTING.
NOTE: Safety switches must be activated to
continue proper operation.
Room Fan
Room fan starts when stove heats up to 110ºF. Will continue to operate until the stove cools 
down to below 90ºF. This may take several 
minutes after fire is out. 
Automatic Shutdown
If after 15 minutes, the stove has not reached 
the preset operating temperature, the unit will 
begin to automatically shutdown.
Should the timer expire before the preset 
operating temperature is achieved, wait 30 
seconds, then simply reset the stove by 
pressing the OFF key.
Normal Operation
If  after  15  minutes  the  preset  operating 
temperature  of  110°F  is  achieved,  normal 
operation will continue.
Operation will continue until either the stoves 
control is to the OFF position, or the operating 
temperature falls below 90ºF. At such time the 
stove will default to the Automatic Shutdown.
SHUTDOWN SEqUENCE OF EVENTS
Once the parlor stove has reached the normal operating temperature and switched to OFF the unit will immediately 
stop feeding fuel and continue safety shutting down for at least 30 minutes.
COMPONENT
SHUTDOWN
OPERATION END
Exhaust Blower
Unchanged operation until preset OFF 
temperature is achieved.
Continues until the operating temperature falls 
below 90º. May take several minutes, up to an 
hour. 
Feed Auger
Auger stops feeding fuel.
NOTE: Safety switches must be activated to
continue proper operation.
Room Fan
Unchanged operation until preset OFF 
temperature is achieved.
Will continue to operate until the heater cools 
down to below 90ºF. This may take several 
minutes. 
Over Temperature Shutdown
If the heater’s HIGH LIMIT sensor detects 
HIGH HEAT, an automatic shutdown is 
activated. 
It is rare that the HIGH LIMIT temperature is 
reached. However, should this error occur, 
let the heater cool down for an hour before 
attempting to restart.