FMC Corporation - Talstar 80 Manual De Usuario

Descargar
Página de 122
Operation
Proline Promass 80 PROFIBUS PA
44
5.6
PROFIBUS PA hardware settings  
5.6.1
Hardware write protection
A jumper on the I/O board provides the means of switching hardware write protection on or off. 
When hardware write protection is switched on, it is not possible to write to the device functions 
via PROFIBUS (acyclic data transmission, e.g. via the operating program "FieldCare").
#
Warning! 
Risk of electric shock. Exposed components carry dangerous voltages. Make sure that the power 
supply is switched off before you remove the cover of the electronics compartment.
1.
Switch off power supply.
2.
Remove the I/O board. 
3.
Configure the hardware write protection accordingly with the aid of the jumpers (see Figure).
4.
Installation is the reverse of the removal procedure.
a0001359
Fig. 29: 
Switching write protection on and off with the aid of a jumper on the I/O board
Jumper for switching write protection on and off
1.1
Write protection switched off (factory setting) = it is possible to write to the device functions via PROFIBUS 
(acyclic data transmission, e.g. via the operating program "FieldCare") 
1.2
Write protection switched on = it is not possible to write to the device functions via PROFIBUS (acyclic data 
transmission, e.g. via the operating program "FieldCare")
2
Jumper without function
LED Overview of LED states:
– Lit continuously 
→ Ready for operation
– Not lit 
→ Not ready for operation
– Flashing 
→ System or process error present → Page 69 ff.
1
1.2
1.1
2
LED