Cabletron Systems CSMIM-T1 Manual De Usuario

Descargar
Página de 198
Chapter 4: CSMIM-T1 Parameters
4-8
CSMIM-T1 Hardware Installation Guide
4.3
T-1 PARAMETERS
The CSMIM-T1 software comes with the following new T-1 parameters:
Keyword
Description
alarmsyslog
Sets or displays parameter setting as yes or no. These 
values enable or disable the alarm event syslogs.
bypass
Sets or displays parameter setting as yes or no. A setting 
of yes removes the T-1 engine from the network.
map
Sets or displays mappings for the DS0 channels. 
ring
Sets or displays parameter setting as yes or no. A setting 
of yes means that an audible ring is sent to the service 
provider for incoming calls.
sigproto
Sets or displays the inbound and outbound signaling 
protocol settings for each DS0 channel.
t1_info
Sets or displays a character string (128 bytes maximum) 
of printable ASCII characters that describe installation 
information from the service provider.
tni_circuit_id
Sets or displays the T-1 circuit identifier string (128 
characters maximum) required by the service provider for 
customer service calls. 
tni_clock
Sets or displays parameter setting as looplocal, or 
external. These values represent the source for the T-1 
clock.
tni_esf_fdl
Sets or displays parameter setting as ansi or att. These 
values represent the Facilities Data Link standard.
tni_framing
Sets or displays parameter setting as d4 or esf. These 
values represent the superframe format setting on the T1 
Network Interface.
tni_line_buildout
Sets or displays parameter setting as 0, 7.5, 15, or 22.5. 
These values represent the cable loss measurement 
between the last line generator and the customer location.