Page 6                                                   High PoE Midspan and Splitters Installation Guide
Installation
1. Connect the AXIS T8123 to an AC outlet (100-240 VAC), using a standard power cable. 
2. Connect the unit Data In jack (input) to your remote Ethernet network switch using an Ethernet 
cable. 
3. Connect the Data & Power Out jack (output) to your Axis splitter or camera, using an Ethernet 
cable.
Indicators
LED
Color
Indication
Port
Unlit
No camera connected
Flashing
Power overload or other input voltage error
Steady green
Camera connected, normal behavior
Green 1 Hz blinking
Over current or short circuit condition on the port
Green 4 Hz blinking
PSE input voltage out of range or other internal fault
AC input
Steady green
AC power connected
Output port
Input port
Camera/splitters
Ethernet
Data and Power out
Data in
Port connectivity
indicator
AC Input connectivity
indicator