AC International MTA128ST-USB Manual De Usuario

Descargar
Página de 108
58
MultiModemISDN User Guide
S-Register: S5
Function:
Backspace Character
Unit:
Decimal ASCII code
Range:
0–32, 127
Default:
8 (^H)
Description: Specifies the character used by the TA to delete the previous character in the
command line.
S-Register: S7
Function:
Wait for Connection (Abort Timer)
Unit:
1 second
Range:
0–255
Default:
45
Description: Sets the Abort Timer delay time, which is the length of time the TA waits for a
connection after dialing. If no connection is established during the specified
time, the TA ends the call.
S-Register: S8
Function:
Pause Time for Comma
Unit:
1 second
Range:
n=0-255
Default:
2 (2 seconds)
Description: S8 sets the length of the pause caused by a comma inserted in a dialing
command.  The default setting is 2 seconds, where each unit is one second.
S8 may be set for up to 255 seconds.
S-Register: S10
Function:
DCD Drop Time
Unit:
50 ms
Range:
0–254, 255
Default:
20
Description: Sets the time after a carrier signal is lost before the TA disconnects. (The
&C2 command must be in effect.) Default setting is one second. Maximum
delay is 25.4 seconds (S10=254). Set S10 to 255 to cause the TA not to
disconnect with loss of carrier.
S-Register: S25
Function:
DTR Drop Time
Unit:
100 ms
Range:
0, 1–255
Default:
5
Description: Sets the time that DTR must remain low before TA disconnects. The S25 unit
value for 0 is 50 ms. For values from 1 through 255, the unit value is 100 ms.