Instruction 0011-9026
Page 12
0-7.6% CO
2
 or O
2
CO
2
 tests of controlled atmospheres in fruit, 
vegetable, and meat storage rooms. Oxygen 
determination in fl ammable gases. Oxygen tests 
to check atmospheres made inert with nitrogen 
(silos, fuel tanks, etc.)
0-20% CO
2
  or 0-21% O
2
Flue gas combustion tests, oxygen defi ciency tests, 
and CO
2
 tests of heat treating atmospheres. 
Checking oxygen concentrations in hydrogen-cooled 
generators and oil-sealed inert-gas transformers.
0-60% CO
2
 or O
2
 
Checking CO
2
 in inert gas blankets in tankers and 
barges carrying gasoline and other com bustibles. 
CO
2
 tests on lime kilns. Checking CO
2
 in sewage 
plant digesters. Oxygen tests in connection with 
oxygen and gas anesthesiology.
5.4   CO
2
 FYRITE Only Combustion Testing
5.4.1   Percent CO
2
 Shows Volume of Excess Air (Refer to Figure 15)
For any given fuel, theoretical maximum percent CO
2
 (Ultimate CO
2
 ) would be pro-
duced when exactly enough air (but no excess air whatsoever) is supplied to burn all 
of the fuel. As increasing amounts of excess air are supplied, percentage CO
2
 naturally 
decreases from theoretical Ultimate CO
2
 due to the diluting effect of excess air.
Thus, measuring percent CO
2
 is also a method of indicating excess air to ensure that 
enough is supplied to permit clean combustion without adding so much that combus-
tion effi ciency is unnecessarily decreased.
5.4.2   Too Much Excess Air Means Ineffi cient Combustion