Brocade Communications Systems Brocade ICX 6650 53-1002599-01 Manual De Usuario

Descargar
Página de 86
Brocade ICX 6650 Hardware Installation Guide
49
53-1002599-01
Power supply specifications
A
Power supply specifications
All units ship with two RPS15 redundant, load sharing, and hot swappable power supplies.The 
power supplies are universal and capable of functioning worldwide without voltage jumpers or 
switches. They meet IEC 61000-4-5 surge voltage requirements and are autoranging in terms of 
accommodating input voltages and line frequencies.
 lists the power state definitions for the Brocade ICX 6650.
 lists the power supply specifications for the Brocade ICX 6650.
Inrush current should be limited to 35A peak for any initial current surge or spike of 10ms or less at 
either cold or warm start. Any additional inrush current surges or spikes in the form of AC cycles or 
multiple AC cycles greater than 10ms and less than 150ms must not exceed 25A peak. After 
150ms the AC input current will be less than the rating of input fuses and the other components 
within the power supply.
General specifications
 lists the general specifications for the Brocade ICX 6650.
TABLE 5
Power state definitions
Power State
Definition
Idle
All ports down, no optics or cables connected.
Typical
56x10 GbE, 4x40 GbE, and 4x4x10 GbE ports linked 
and UP. 10% traffic with 64-byte packets. Fans at normal 
speed.
Maximum 
All ports connected with optics to draw maximum power 
per MSA Optics Specification. Traffic at full rate or 100% 
throughput. Fans at full speed.
TABLE 6
System power specifications
AC Voltage
Input Watts
BTU’s/hr
Power State
120 VAC
114.6
391.14
Idle
120 VAC
154.6
527.66
Typical
120 VAC
230
785.01
Maximum
TABLE 7
General specifications
Specification
Description
System architecture
Nonblocking shared-memory switch
System processor
800 MHz PowerPC
Switch bandwidth
1600 Gbps
Forwarding bandwidth (data rate, full 
duplex)
1190 Mpps