Westinghouse WGC055NG100 Instruccion De Instalación

Descargar
Página de 59
47 
 
 
                                                                                 WHL-019 REV. 12.17.14 
 
 
Figure 27 - NOTE: The maximum tank temperature is 160
o
F, independent of all settings described above.
 
E. TEST MODE 
This function is intended to simplify the gas valve adjustment if needed. Listed below are the recommended limits on each heater and 
the combustion settings. Automatic modulation does not take place when the controller is in Test mode, only temperature limitation 
based on the heater set point. The user will be allowed to increase or decrease the fan speed by pressing in either the 
{S1}
 or 
{S2}
 
keys. 
 
To activate the Test Mode simply press the 
{S2}
 and 
{S3}
 key together for 1 second. Once activated, you will see in the display 
{Ser}
 
and the actual fan speed. The measurement of the combustion levels should always be taken at the highest and lowest fan speed. 
When in Test Mode, the heater
’s limit will shut down the burner if temperature limit is exceeded. It is recommended to draw water out of 
the tank to lower temperature so tests can be performed. 
 
After 10 minutes, Test Mode stops automatically. To exit Test Mode manually, press 
{S1}
 and 
{S2}
 key together for 1 second. 
 
COMBUSTION SETTINGS ON ALL MODELS 
 
Natural Gas 
Propane LP 
Fan Speed 
Low 
Ignition 
High 
Low 
Ignition 
High 
Carbon Monoxide PPM 
– 10 
2 - 15 
– 20 
– 10 
2 - 15 
– 20  
Carbon Dioxide (CO
2
8 - 10% 
– 10% 
8 - 10% 
8 ½ - 10 ½% 
8 ½ - 10 ½% 
9 - 11% 
Table 11 
FAN SPEEDS 
BTU 
IGNITION 
MIN 
MAX 
100,000 
3000 
2000 
5700 
130,000 
3000 
2000 
7300 
160,000 
3000 
2000 
7450 
199,000 
3000 
2000 
9100 
Table 12 
F. MAINTENANCE 
The control system requires no periodic maintenance under normal conditions. However, in unusually dirty or dusty conditions, periodic 
vacuuming of the cover to maintain visibility of the display and indicators is recommended. In dirty environments, such as construction 
sites, care must be taken to keep the water heater burner cover in place and drywall or saw dust away from water heater. 
 
 
In unusually dirty or dusty conditions, care must be taken to keep water heater burner door in place. Failure to do so VOIDS 
WARRANTY!
 
 
 
Allowing the heater to operate with a dirty combustion chamber will hurt operation. Failure to clean the heat exchanger as needed by 
the installation location could result in heater failure, property damage, personal injury, or death. Such product failures ARE NOT 
covered under warranty. 
du setting 
Function 11 
/ Function 9 
Fun
c
tion
 8
 
Fun
c
tion
 10
 
Function 12