Siemens AC75 Manual De Usuario

Descargar
Página de 569
AC75 AT Command Set  
19.5 AT^SBV
s
AC75_ATC_V01.002
Page 489 of 569
10/30/06
Confidential / Released
 
19.5
AT^SBV Battery/Supply Voltage
The 
 execute command allows to monitor the supply (or battery) voltage of the module. The voltage is
continuously measured at intervals depending on the operating mode of the RF interface. The duration of a mea-
surement period ranges from 0.5s in TALK / DATA mode up to 50s when AC75 is in IDLE mode or Limited Ser-
vice (deregistered). The displayed value is averaged over the last measuring period before the 
command was executed. 
The measurement is related to the reference points of BATT+ and GND, both accessible on a capacitor located
close to the module's board-to-board connector. For details please refer to the Hardware Interface Description
Syntax
Parameter Description
Supply (or battery) voltage in mV 
Test Command
AT^SBV=?
Response(s)
OK
ERROR
+CME ERROR:
Exec Command
AT^SBV
Response(s)
^SBV: 
OK
ERROR
+CME ERROR:
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS
-
+
+
+
+
+
+
-
+
-
<value>
(num)