Home Automation HAI (Home Automation Inc.) Home Security System 20A00-1 Manual De Usuario

Descargar
Página de 68
 
Page 51 
 
 
 
OMNI II SPECIFICATIONS 
 
Size:  Controller:  13 W x 13 H x 4.5 D 
       Console:   4.6 W x 4.5 H x 1.2 D 
 
Weight:  Controller:  approx. 10 lb. 
         Console:     approx. 0.5 lb. 
 
Operating     32 - 122 degrees F (0 - 50 degrees C) 
Ranges:       10 - 95 % relative humidity, non-condensing 
 
Power:        120 VAC, 60 Hz, 60 watts 
 
Transformer:  24 VAC, 1.67 amps, 40 VA 
 
Battery:      Rechargeable Lead-Acid, 12 volts, 7 amp-hour 
 
Device Fuse:  Polyfuse:  1.35 A 
 
Horns Fuse:   Polyfuse:  1.35 A 
 
Battery Fuse: Polyfuse:  4.00 A 
 
Polyfuses are permanent fuses that do not need replacement. 
 
Nominal Voltage:       10 - 13.7 VDC, 0.5 V max. peak to peak ripple 
 
Low Voltage Cut Out:   approx. 9 VDC 
 
Typical Current Consumption at Nominal Voltage: 
 
 
 
Controller:  135 mA 
 
 
Console: backlight off - 35 mA; backlight on - 100 mA 
 
Controller Maximum Group Current Outputs: 
 
Devices:   AUX 12 VDC, SWITCH 12 VDC, CONSOLE, and OUTPUTS 1 - 8: 1 A 
 
Horn:      INT HORN and EXT HORN: 1 A 
 
Controller Maximum Individual Current Outputs: 
 
Devices:   (Do not exceed 1 A total) 
        
       AUX 12 VDC                        1 A 
       SWITCH 12 VDC                     1 A 
       CONSOLE                           1 A 
       OUTPUTS 1 - 8                     100 mA 
 
 
For 24-Hour Battery Standby Time, the following must be observed: (See Figure 15) 
 
Controller Maximum Group Current Outputs (applies to residential and commercial): 
 
Devices:   AUX 12 VDC, SWITCH 12 VDC, CONSOLE, and OUTPUTS 1 - 8: 250mA 
 
Horn:      INT HORN and EXT HORN: 300mA