Graco 332453C - ExactaBlend AGP Advanced Glazing Proportioner Manual De Usuario

Descargar
Página de 18
Installation 
6
332453C
Calibration Check Assembly, 
24R777
1.
Perform the Shutdown procedure in the Exact-
aBlend AGP Advanced Glazing Proportioner, 
Setup-Operation manual.
2.
Install the hose clamps onto the boom assembly. 
Hand tighten all hose clamps. Refer to Calibration 
Check Assembly, 24R777
page 14, for correct 
screw locations.
NOTE: The base material tube is 0.5 in. (1.3 cm) in 
diameter. Verify the hose clamps are installed on the 
correct side of the boom assembly.
3.
Remove the pressure gauges and fittings.
4.
Install the tube fittings. Tighten the fittings to prevent 
leaking.
5.
Install the material tube lines onto the boom assem-
bly. Tighten all fittings to prevent leaking.
6.
Install the check valve assembly onto the tube lines. 
Tighten all fittings to prevent leaking.