Graco 332453C - ExactaBlend AGP Advanced Glazing Proportioner Manual De Usuario

Descargar
Página de 18
Operation
332453C
9
Operation
USB Kit, 24R936
When a USB memory device is inserted into the USB 
module, a status icon will appear on the DM screen. The 
icon will appear as shown when downloading is com-
plete.
Data
Error Codes
This file shows the date, time, error/event codes, and the 
status of the codes. Refer to DM Error Codes within the 
ExactaBlend AGP Advanced Glazing Proportioner, 
Setup-Operation manual for code information.
NOTE: The codes will have the following for the status 
column:
“0” - Error/event was generated
“1” - Machine acknowledged the error/event. There is no 
user acknowledgement required.
“2” - User acknowledged the error/event.
Run Data
This file shows the date, time, target ratio, actual ratio, 
average flow rate, and both pump A and pump B chemi-
cal dispenses. All chemical dispense values are shown 
in kilograms. The information is recorded at 5 second 
intervals.
NOTE: The data is recorded only when the system is in 
the “OK” state and during normal run mode dispensing.
Software Data
This file shows the date, time, part number, and soft-
ware versions currently installed on the machine.
NOTE: The file will only show the information when the 
download depth is set to “0”.