Siemens TV Converter Box 611 Manual De Usuario
Technical data and characteristics
14.2 Data sheets and diagrams
14.2
Data sheets and diagrams
14.2.1
1FW6090-xxxxx-xxxx
Data sheet 1FW6090-xxB05-xxxx
Table 14- 1 1FW6090-xxB05-0Fxx, 1FW6090-xxB05-0Kxx
Technical data
1FW6090
1FW6090
Symbol
Unit
-xxB05-0Fxx -xxB05-0Kxx
Boundary conditions
DC link voltages
U
ZK
V
600
600
Water cooling intake temperature
T
VORL
°C
35
35
Rated temperature of winding
T
N
°C
130
130
Rated data
Rated torque
M
N
Nm
113
109
Rated current
I
N
A
5.6
7.4
Maximum speed at rated torque
n
MAX,MN
rpm
140
250
Rated power loss
P
V,N
kW
2.19
2.12
Limit data
Maximum torque
M
MAX
Nm
179
179
Maximum current
I
MAX
A
9.5
13
Electric power of motor at M
MAX
P
EL,MAX
kW
6.55
8.12
Maximum speed at maximum torque
n
MAX,MMAX
rpm
46
140
No-load speed
n
MAX,0
rpm
310
430
Torque at n = 1 [rpm]
M
0
Nm
119
119
Current at M
0
and n = 1 [rpm]
I
0
A
5.9
8.2
Thermal static torque
M
0
*
Nm
84.1
84.1
Thermal stall current
I
0
*
A
4.1
5.6
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
20.8
15
Voltage constant
k
E
V/(1000/min)
1258
906.2
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
2.64
2.68
Thermal time constant
t
TH
s
60
60
No. of pole pairs
p
-
22
22
Cogging torque
M
COG
Nm
1.2
1.2
Stator mass
m
S
kg
6.6
6.6
Rotor mass
m
L
kg
2.6
2.6
Rotor moment of inertia
J
L
10
-2
kgm
2
1.52
1.52
Phase resistance of winding at 20 °C
R
STR, 20
Ω
14.9
7.5
Phase inductance of winding
L
STR
mH
47.1
24.4
1FW6 Built-in torque motors
204