Siemens TV Converter Box 611 Manual De Usuario
Installation drawings/Dimension drawings
15
15.1
Installation conditions for motors with cooling jacket
Design information for installation hole and O ring
● Provide insertion inclines: Minimum length Z at 15°: 3 mm, at 20°: 2 mm, edges rounded
and polished
Debur and round inside holes (cooling water connections)
● Surface quality of the opposite sealing surfaces: R
max
≤ 16 µm, R
z
≤ 10 µm, R
a
≤ 1.6 µm
● Note the installation hole fit (H8). If the play is too great, the O-ring does not provide
sufficient sealing or the permissible gap is too large.
5RXQGHGDQGSROLVKHG
'HEXUUHGDQGURXQGHG
Figure 15-1 Design information for installation hole and O ring
1FW6 Built-in torque motors
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7
301