44
System Parameter List
Note 1:
This is the version number of models with the same System Exclusive Model ID = 11-02. This value is used to specify 
the model for a parameter send request from an external source. 
Note 2: 
This is a request to look up and cancel the tone status of parts whose bits are set. It does this by canceling the DSP Line 
selection of the parts whose corresponding bit is 1. 
20.2
Data Management Command Parameter List 
System Exclusive Format
ParamID Parameter
ps
index bit
Value
Default Setting Value 
(Decimal)
00r
Model Version ID (Note 1) 0000
00
0E
05
0
nn00 = reserved 
nn01 = CTK-691 
nn02 = WK-3000 
nn03 = WK-3500
nn04 = reserved
nn05 = CTK-900
nn06 = WK-3200
nn07 = WK-3700
n = version (00 to 3F) 
03
DSP Bypass (Note 2) 0000
00
10
0-FFFF
0
Bit0...Part1
Bit1....Part2 
:
Bit15...Part16 
0...Nop 
1...DSP cancel
Field
Value
01
SYSEX
F0
02
MAN
44
03
MOD
11,02
04
dev
Either 00 to 1F, or 7F
05
act
00(IPC), 01(IPR)
06
cat
Command = 0
07
prm
00-7F
08
ilen/dlen 0 / bit size - 1
09
ps
0
10
index
0
11
data
(See the Parameter List)
12
sum
None
13
EOX
F7