Compex Systems SA33-3285-02 Manual De Usuario

Descargar
Página de 531
Swap Members of an SSA RAID Array
For fast path, type
smitty exssaraid
and press Enter.
Otherwise, select Swap Members of an SSA RAID Array from the Change Member
Disks in an SSA RAID Array menu.
When the List key is pressed for the Disk to Remove option, the following pop-up
menu is displayed:
SwapMembers of an SSA RAID Array
Type or select values in entry fields.
Pr --------------------------------------------------------------------------
|
Disk to Remove
|
|
|
| Move cursor to desired item and press Enter.
|
|
|
|
#################################################
|
|
# Primary Disks
|
* |
pdisk0
AC7AA078 04-07-P
present
9.1GB
|+
* |
pdisk6
AC7AA8A4 04-07-P
present
9.1GB
|+
|
#################################################
|
|
# Secondary Disks
|
|
pdisk9
AC7AD176 04-07-P
present
9.1GB
|
|
pdisk10
AC7AE3C9 04-07-P
present
9.1GB
|
|
#################################################
|
|
# Coupled Disks
|
|
pdisk11
AC7AE417 04-07-P
present
9.1GB
|
|
pdisk12
AC7AE41C 04-07-P
present
9.1GB
|
|
|
| F1=HelpF2=Refresh
F3=Cancel
|
F1| F8=Image
F10=Exit
Enter=Do
|
F5| /=Find
n=Find Next
|
F9 --------------------------------------------------------------------------
The status values for coupled disks are:
present
The disk drive is present and operational.
not_present
The disk drive is missing or has failed.
Chapter 7. Copying Data from Arrays and from Volume Groups
191
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|