Example 7: To Change an Attribute of an Object
This example shows how to change an attribute of an object; for example, to change
the new array so that it does not automatically call a hot spare disk drive if one of its
member disk drives goes into the Offline state.
Type the command:
> ssaraid -H -l ssa0 -n hdisk5 -a spare=false
where:
-H
specifies that this operation is a change operation.
-n hdisk5
specifies that the object hdisk5 is about to be changed.
-a spare=
specifies the new value for the spare attribute.
A list of user-changeable attributes are available from “Hot Spare Pool Creation and
Change Attribute” on page 249.
Example 8: To Exchange a Member Disk Drive of an Existing Array
This example shows how to exchange a member disk drive of an existing array with a
free pdisk; for example, to exchange pdisk0 with pdisk3.
Type the command:
> ssaraid -A -l ssa0 -i exchange -n hdisk5 -a old_member=pdisk0 new_member=pdisk3
where:
-A
specifies that this operation is an exchange operation.
-n hdisk5
specifies that the array about to be changed.
-a old_member=
specifies the name of the existing member disk.
-new_member=
specifies the name of the new member disk drive.
If you give a List command in summary format, a result similar to that shown here is
displayed:
pdisk0
0004AC506C4000D free
n/a
4.5GB
Physical disk
pdisk1
0004AC506D6D00D member
n/a
4.5GB
Physical disk
pdisk2
0004AC50A44200D member
n/a
2.3GB
Physical disk
pdisk3
0004AC515EA400D member
n/a
4.5GB
Physical disk
hdisk5
900335FE80C84CK rebuilding
9.0GB
RAID-5 array
242