Compex Systems SA33-3285-02 Manual De Usuario

Descargar
Página de 531
ssaencl Command
Purpose
To allow the monitoring and changing of the status for SSA SES disk enclosures
(subsystems).
Syntax
To display enclosure component settings:
ssaencl -l name [-s] [-v] [-i] [-r] [-b [card ...]] [-t [threshold ...]]
[-a] [-f [fan ...]] [-d [drive_bay ...]] [-p[PSU ...]]
[-o] [-c] [-e]
To modify enclosure component settings:
ssaencl -l name [-I ID [-U]] [-B mode | card=mode ...] [-S{d[drive_bay ...] |
b[card...] | p[PSU ...] | r | c | o }] [-T threshold=value ...]
To display a usage message:
ssaencl -h
ssaencl -?
Description
The ssaencl command can be used to observe the existing settings of an SSA SES
disk enclosure (subsystem), or to modify the settings of that enclosure. The command
can be used only to observe or modify settings; it cannot be used to observe and
modify settings at the same time.
When the command displays enclosure settings, it displays them in tables that the user
can read easily. If the -s flag is specified, however, the command displays the settings
in colon-separated format, as used by commands such as the SMIT commands.
Flags
-l name
Specifies the name of an SSA SES enclosure or pdisk. If a pdisk name is
used, that pdisk must be in an SSA SES enclosure.
-s
Displays output in colon-separated format.
-v
Displays also VPD information.
-i
Displays the enclosure identifier (as shown in the operator panel, if present).
-r
Displays “RPO present TRUE/FALSE” (RPO is the remote power-on control)
-b [card]
Displays the status of the bypass cards. If no parameters are given, the status
for all the bypass cards is displayed. Valid values for the [card] parameter are:
1, 4, 5, 8, 9, 12, 13, 16.
Chapter 16. Using the SSA Command Line Utilities
355
|
|
|
|
||