Bunn FPG-2 Manual De Usuario

Descargar
Página de 79
54
SERVICE (Cont.)
EMI Filter (Models FPG & FPG-2)
FIG 60 EMI FILTER
FIG 61 EMI FILTER TERMINALS
Location:
 
The EMI Filter is located inside the rear cover of the 
grinder housing.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the two red wires and two white wires on 
the EMI Filter from the EMI Filter wiring harness.
3.  Check for resistance between the two red leads on 
the EMI Filter. (Fig 61)   
If resistance is present as described the EMI Filter is 
operating properly.
If resistance is not present as described, replace the 
EMI Filter.
Removal and Replacement:
1.  Disconnect the wires from the EMI Filter.
2.  Remove the two screws securing the EMI Filter.
3.  Remove and discard EMI Filter.
4.  Install new EMI Filter using two screws to secure 
EMI Filter to its former location.
5.  Refer to schematic when reconnecting the wires.
118.0 kΩ - 118.5 kΩ
Across either pair
GRINDER
  D
BC
®
41545 122209