Breckwell P4000 Manual De Usuario

Descargar
Página de 27
 
OPTIONAL THERMOSTAT 
 
A thermostat may help you maintain a constant house temperature 
automatically. A millivolt thermostat is required. A fixed wall mount 
or Breckwell’s hand held model can be used. The control panel can 
be set up two ways to operate your stove in thermostat mode. 
 
NOTE: YOUR THERMOSTAT SHOULD BE INSTALLED BY AN 
AUTHORIZED DEALER OR SERVICE PERSON. 
THERMOSTAT INSTALLATION 
 
• 
A MILLIVOLT THERMOSTAT IS REQUIRED. 
• 
Unplug stove from power outlet. 
• 
Remove control board from stove. 
• 
The two thermostat wires connect to the terminal block on the 
lower left side of the back of the control board. 
        (See figure 14) 
• 
Insert the wires in the terminal side and tighten the two screws. 
MODES 
 
TO SWITCH BETWEEN ANY OF THE THREE MODES THE 
STOVE MUST BE SHUT OFF, THE NEW MODE SELECTED, AND 
THE STOVE RESTARTED. 
 
MANUAL  MODE 
• 
In this mode the stove will operate only from the control panel 
as detailed in the “
OPERATION
” section of this owner’s 
manual. 
 
HIGH/LOW THERMOSTAT MODE 
• 
When engaged in this mode the stove will automatically switch 
between two settings. When warm enough, it will switch to the 
#1 or low setting. The room air blower will also slow to its 
lowest speed. 
• 
The Heat Level Advance setting on the bar graph will stay 
where it was initially set. When the house cools below the 
thermostat setting, the stove will switch to the feed rate of the 
heat level advance setting. 
 
ON/OFF THERMOSTAT MODE 
• 
In this mode when the home is warm enough the stove will 
shut off. The fans will continue to run until the stove cools. 
• 
When the home cools below the thermostat setting, the stove 
will automatically restart and run at the last feed rate setting. 
 
 
NOTE: When in “high/low” or “on/off” thermostat mode – 
• 
Do not operate the stove higher than the #3 setting. 
• 
Set damper control rod approximately ½” to ¾” out. This will 
vary depending on elevation and weather conditions. Observe 
stoves operation and adjust damper as necessary. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
THERMOSTAT INSTALLATION 
14 
FIGURE 14