Gaggenau AI442720 Guía De Instalación

Descargar
Página de 60
16
3
Extraction mode units with external remote fan unit 
AR 4..:
‒ Unscrew the connecting pieces from the cover 
plate in the ventilation hood.
‒ Secure the exhaust air pipe to the connecting 
piece 
(A)
.
‒ Screw the connecting piece to the cover plate in 
the ventilation hood.
4
Connect it to the air extractor opening 
(B)
.
5
Seal the joints appropriately.
Connecting the power supply
1
Plug the mains plug into the grounded socket.
2
If a fixed connection is required, please follow the 
instructions in the 
Electrical Connection
 section.
Attaching flue duct
9
WARNING
Risk of injury
Components inside the appliance may have sharp 
edges. Wear protective gloves.
1
Remove the protective film from the flue ducts.
2
Place both parts of the upper flue duct on the 
appliance such that they fit together. 
Model with air extraction mode
Models with air recirculation mode
3
Push the upper flue duct up and use two screws to 
secure it at the top. 
$5
$
%