Whirlpool AKM260IX Prospecto

Descargar
Página de 2
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE:  In case of installation of a hood above the cooktop, please refer to the hood 
instructions for the correct distance.
INJECTORS TABLE
CATEGORY II2H3+
ELECTRIC SUPPLY: 230V - 50Hz
Type of gas used
Type of 
burner
Injector 
marking
Rated 
heat 
capacity
kW
Rated 
consumption
Reduced 
heat 
capacity 
kW
Gas pressure mbar
min.
rat.
max.
NATURAL GAS
(Methane)
G20
large
medium
small
128
94
76
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17
20
25
LIQUID PETROLEUM 
GAS
(Cylinder)
G30
large
medium
small
85
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
20
28-30
35
LIQUID PETROLEUM 
GAS
(Cylinder)
G31
large
medium
small
85
65
50
3.00
1.65
1.00
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
25
37
45
Type of gas used
Appliance
model
Total rated heat 
capacity kW
Total rated 
consumption
Air required
for burning
m
3
/h
G20 20 mbar
4 gas
7.30
695 l/h
14.6
G30 28-30 mbar
4 gas
7.30
531 g/h
14.6
G31 37 mbar
4 gas
7.30
521 g/h
14.6