Technical Data
Total connected load electric: 25 VA
Nozzle Table Wok Burner
Nozzle Table Large Burner
Nozzle Table Small Burner
Installation Procedure
Prepare Installation Space
Create the cut-out in the countertop for one or several 
Vario appliances according to the installation diagram. 
The angle of of the cut surface to the countertop must 
be 90°.
After creating cut-out, remove shavings. Seal cut 
surfaces in a heat-resistant manner.
Some solid surface countertops require special 
installations. For example, heat reflective tape and 
rounded corners may be necessary. Contact the 
countertop manufacturer for instructions specific to 
your countertop.
Observe minimum distance between appliance 
underside and furniture parts of 
3
/
8
" (10 mm).
When installing multiple Vario appliances: 
Take into 
account space requirement for VV 200 connection 
strip between the appliances. Appliances can also be 
installed in individual cut-outs, bearing in mind a 
minimum distance between the appliances of 1
9
/
16
(40 mm).
Install Appliance
,
WARNING: 
Before you plug in an electrical cord 
or turn on power supply, make sure all controls 
are in the OFF position.
Air intake from above. No intermediate shelf required.
Stovetop clamping range: 30 - 50 mm.
1
Cut out an opening in the countertop according 
to the installation drawing. Check the minimum 
clearance from the rear wall and the sides of 
kitchen units. Seal the edges of the cut-out. 
2
Turn the clamp fasteners to the side. Place the 
gas hotplate into the cut-out and align it evenly.
3
Tighten all clamp fasteners evenly. Check that the 
whole frame lies evenly flat on the countertop.
4
Fit the burner rings, burner lids and pan supports.
5
Connect the appliance to the gas and electricity 
supply. The appliance is not operable without 
power supply.
6
Test the appliance for correct functioning. There 
might be an air pocket in the gas supply line if the 
appliance turns off and the indicator lights flash. 
Turn all control knobs to 0 and ignite the burner 
again.
Gas
Natural Gas 
Type N
LPG (Propane) 
Type X
Pressure
6" water col-
umn (1.5 kPa)
10" water col-
umn (2.5 kPa)
Nozzle, full burn, outer
173
110 A
Nozzle, low burn, outer
75
56
Nozzle, full burn, inner
60
42
Nozzle, low burn, inner
48
34
Air gap adjustment, outer 0 mm
2 mm
Total connected load
59 700 BTU 
(17.5 kW)
58 000 BTU 
(17 kW)
Total consumption
1.67 m³/h
1160 g/h
Gas
Natural Gas 
Type N
LPG (Propane) 
Type X
Pressure
6" water col-
umn (1.5 kPa)
10" water col-
umn (2.5 kPa)
Nozzle, full burn, outer
150
105
Nozzle, low burn, outer
65
45
Nozzle, full burn, inner
40
29
Nozzle, low burn, inner
42
28
Air gap adjustment, outer 0 mm
2 mm
Total connected load
59 700 BTU 
(17.5 kW)
58 000 BTU 
(17 kW)
Total consumption
1.67 m³/h
1160 g/h
Gas
Natural Gas 
Type N
LPG (Propane) 
Type X
Pressure
6" water col-
umn (1.5 kPa)
10" water col-
umn (2.5 kPa)
Nozzle, full burn, outer
97
68
Nozzle, low burn, outer
48
34
Nozzle, full burn, inner
40
29
Nozzle, low burn, inner
42
28
Air gap adjustment, outer 0 mm
open at MAX
Total connected load
59 7000 BTU 
(17.5 kW)
58 000 BTU 
(17 kW)
Total consumption
1.67 m³/h
1160 g/h