Technical Data
Total connected load electric: 0.8 VA
Installation Procedure
Prepare Installation Space
Create the cut-out in the counter top for one or several 
Vario appliances according to the installation diagram. 
The angle of of the cut sur face to the counter top must 
be 90°.
After creating cut-out, remove shavings. Seal cut 
sur faces in a heat-resistant manner.
Some solid sur face counter tops require special 
installations. For example, heat reflective tape and 
rounded corners may be necessar y. Contact the 
countertop manufacturer for instructions specific to 
your counter top.
Obser ve minimum distance between appliance 
underside and furniture par ts of 
3
/
8
" (10 mm).
When installing multiple Vario appliances: 
Take into 
account space requirement for VV 200 connection 
strip between the appliances. Appliances  can  also be 
installed in individual cut-outs, bearing in mind a 
minimum distance between the appliances of 1
9
/
16
(40 mm).
Install Appliance
,
WARNING: 
Before you plug in an electrical cord 
or turn on power supply, make sure all controls 
are in the OFF position.
1
Make a mark exactly in the center of the cut-out. 
Fasten the mounting rails to the front and rear 
edge of the cut-out. The leading edges of the 
mounting rails must lie upon the worktop. The 
center marking of the mounting rails must 
correspond precisely with the center marking of 
the cut-out.
Note: 
For natural stone worktops, adhere the 
mounting rails with temperature-resistant duel-
component adhesive (metal on stone).
2
For combination with the VD 201 device cover: 
Mount device cover to device prior to installation 
(see VD 201 Installation Instructions).
3
Inser t device in cut-out. The latching lugs on the 
device must lie precisely on the clamp springs. 
Press device firmly into the cut-out. 
The latching 
lugs on the device must snap into the clamp 
springs.
Gas
Natural Gas 
Type N
LPG (Propane) 
Type X
Pressure
6" water 
column 
(1.5 kPa)
10" water 
column 
(2.5 kPa)
C
 Nozzle, full burn, outer
173
110 A
A
 Nozzle, low burn, outer
79
57
D Nozzle, full burn, inner
60
42
B Nozzle, low burn, inner
42
31
Air gap adjustment, outer
2 mm
0 mm
Total connected load
18 800 BTU 
(5.5 kW)
17 000 BTU 
(5 kW)
Total consumption
0.52 m³/h
364 g/h