2
Verifying the Package Contents
Please contact your dealer immediately if
components are missing.
• Use and Care Manual
• Mounting Brackets
• Cleaning Creme
• Glass Scraper
• Foam Tape
Power Disconnection
WARNING:
Failure to disconnect power may
result in electrical shock or fire
hazard! If the electric service
provided does not meet the
product specifications, do not
proceed with the installation. Call
the selling dealer or a licensed
electrician
Electrical Power Supply
Requirements
It is the owner’s responsibility to ensure that
the electrical connection of this appliance
is performed by a qualified electrician. The
electrical installation, including minimum supply
wire size and grounding, must be in accordance
with the National Electric code ANSI/NFPA 70-
1993* (or latest revision) and local codes and
ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and amperage
must be supplied to the appliance from a
separate, grounded, circuit that is protected by a
properly sized circuit breaker or time delay fuse.
Refer to the data plate located on the bottom
of the chassis, and/or to Table 1 below, for
electrical supply requirements.
Model No.
Electrical Circuit Required
Total Connected
Load
Minimum Supply Wire Size
Line and Ground Connections
CER304
240VAC, 60Hz, 40A
6.9kW (29A)
No. 8 AWG
208VAC, 60Hz, 40A
6.9kW (33A)
CERB365
240VAC, 60Hz, 50A
9.6kW (40A)
208VAC, 60Hz, 50A
9.6kW (46A)
ETT304
240VAC, 60Hz, 30A
6.9kW (29A)
ETT365
240VAC, 60Hz, 40A
8.9kW (37A)
ETT365S
MET304
MET304
6.9kW (29A)
METB365
240VAC, 60Hz, 50A
9.6kW (40A)
Electrical Supply Requirments
Countertop Preparation
WARNINGS:
1. To reduce the risk of personal
injury caused by reaching
over a hot appliance, cabinet
storage space located directly
above the cooktop should be
avoided.
2. Do not store combustible
materials or items adversely
affected by heat in cabinet
areas above the appliance.
3. Failure to provide proper
clearances may result in a fire
hazard!
NOTES:
1. If cabinet storage space is to
be provided directly above the
cooktop, the risk of personal
injury may be reduced by
installing a ventilating hood
that projects horizontally a
minimum of 5 inches beyond
the face of the cabinets.
2. Allow a minimum 2-inch
clearance between the bottom
of the cooktop chassis and
any combustible surface,
including the upper edge of
a drawer installed below the
cooktop.
3. Access to the underside of
the cooktop and the junction
box must be provided for
inspection and service.
6" (152mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2" (51mm) Min.
to combustibles
below chassis
4" (102mm)
Chassis height
28 1/2" (724mm)
2" (51mm)
21" (533mm)
30" (762mm)
Vertical
Combustible
Surface
3 1/8"
(79mm)
Rear Wall
2 1/4"
(57mm)
Min.
19 7/8" (505mm)
25" (635mm)
6" (152mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2" (51mm) Min.
to combustibles
below chassis
4" (102mm)
Chassis height
34 1/2" (876mm)
2"
(51mm)
25" (635mm)
21"
(533mm)
36" (914mm)
Vertical
Combustible
Surface
3 1/8"
(79mm)
Rear Wall
19 7/8" (505mm)
2 1/4"
(57mm)
Min.
Cutout Dimensions for the CER304, ETT304, and MET304
(CER304 shown)
Cutout Dimensions for the CERB365, ETT365, ETT365S, and METB365
(ETT365 shown)