6
Cabinet/Countertop Dimensions (cont.)
Installation Requirements
Cutout tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
Non-combustible 
rear wall, rear of 
mounting platform
10” (254 mm) min. 
to combustible wall 
above countertop, 
both sides
Cabinet face 
below countertop 
overhang
Increase countertop and overhang  
additional 2 1/2” (64 mm) Min. for 
combustible rear wall  above 
countertop
3/8” (13 mm) 
countertop overhang
Hole 1/2” dia. (13 mm), 
2 places, through platform
for hold down bolts 
Gas/electrical utility cut-out in right rear corner of 
mounting platform 8” W X 6” D (203 mm X 152 mm),
if gas and electrical are routed through bottom
1/2” (13 mm) 
countertop 
overhang
1” thick mounting platform Min.
Countertop
Countertop
1/2” (13 mm) 
countertop 
overhang
2” (51 mm)
1” (25 mm)
11 7/16” 
(291 mm)
24 5/8” 
(625 mm)
CL
D
D
B
CL
CL
CL
Cooktop 
Model
B - Cutout 
Width
D - Hole 
Offset
E - Raised 
Vent Cutout
Approved Raised 
Vent Models
EG366
36” 
(914 mm)
16 5/8” 
(422 mm)
33 1/2” 
(851 mm)
ERV36, PRV36
EG486
48” 
(1219 mm)
20 13/16” 
(529 mm)
43 1/2” 
(1105 mm)
ERV48, PRV48
Cabinet/Countertop Cutout Dimensions without Raised Vent - Top View
Gas connection and power cord may be 
routed through bottom or back of chassis
Gas and electrical connections at 
right rear section of chassis
IMPORTANT: Use only the raised vent models specified.