NOTE: The 7" (17.8 cm) round vent mounting plate and 
3
¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent connector can 
be installed up to 1" (2.5 cm) on either side of the hood 
center to accommodate off center ductwork.
If a vent damper is installed with a wall cap with damper, 
check to make sure they do not interfere with each other.  
Remove the vent connector damper flap if they interfere.
Non-vented (recirculating) installations - No vent 
attachments. The UXT42 and UXT52 series models 
require the removal of the recirculation cover plate. 
Remove the two screws from the recirculation cover plate 
and remove.
Power Supply Cable Installation
1. For direct wire installations, run the home power supply cable 
according to the National Electric Code or CSA standards 
and local codes and ordinances. There must be enough 
wiring from the fused disconnect (or circuit breaker) box to 
make the connection in the hood electrical terminal box.
For optional power supply cord kit installations, follow the 
instructions included with the power supply cord kit.
NOTE: Do not reconnect power until the installation is 
complete.
2. Remove the screw from the terminal box cover. Remove 
terminal box cover and set aside. 
3. Remove the power supply knockout from the top or rear of 
the vent hood (depending on the incoming location of your 
home power supply cable) and install a UL listed or CSA 
approved 
¹⁄₂” strain relief.
4. Using 2 or more people, lift the hood into final position. Feed 
enough electrical wire through the ½" UL listed or CSA 
approved strain relief to make connections in the terminal 
box. Tighten the strain relief screws. 
5. Position the range hood so that the large end of the keyhole 
slots are over the mounting screws. Then push the hood 
toward the wall so that the screws are in the neck of the slots. 
Tighten the mounting screws, making sure the screws are in 
the narrow neck of slots.
6. Connect ventwork to hood. Seal joints with vent clamps or 
duct tape to make secure and airtight.
7. Check that back draft dampers work properly.
A. Vertical connector
B. 6.5 x 9.5 mm screws
C. Vent knockouts
D. Horizontal connector
A. Recirculation cover plate
B. Screws
B
A
B
D
C
A
B
A. Terminal box cover
B. Screw
A. Power supply knockout
A
B
A