Kegco Commercial Deep Well Bottle Cooler - 18 cu. ft. Capacity Manual De Usuario

Descargar
Página de 9
www.kegco.com 
1-888-980-4810 
Installation Instructions 
 
BEFORE USE: 
•  Remove the exterior and interior packaging. 
•  Before connecting the unit to the power source, let it stand upright for approximately 24 hours. This will reduce 
the possibility of a malfunction in the cooling system from handling during transportation. 
•  Clean the interior surface with lukewarm water using a soft cloth.  
•  This appliance is designed for freestanding use. A space of at least 4” should be allowed between the 
surrounding walls and the cabinet wall for air circulation. 
•  Place the unit on a flat, solid floor that is strong enough to support it when it is fully loaded  
•  When moving your refrigerator, please do not incline it more than 45 degrees.  
•  Locate the appliance away from direct sunlight and sources of heat (stove, heater, radiator, etc.). Direct sunlight 
may affect the acrylic coating and heat sources may increase electrical consumption. Extreme cold ambient 
temperatures may also cause the unit to perform improperly.  
•  Install the unit in a dry place to prevent rust from forming on the compartment body, which may affect the 
electrical insulation. 
•  Plug the cooler into an exclusive, properly installed and grounded wall outlet. Do not under any circumstances 
cut or remove the third (ground) prong from the power cord. Any questions concerning power and/or electrical 
grounding should be directed to a certified electrician or authorized products service center. 
•  After plugging the appliance into a wall outlet, allow the unit to cool down for 3 to 4 hours before stocking it 
with beverages.
  
 
SEALING THE CABINET TO THE FLOOR: 
This method may be used when sanitation codes require sealing the cooler to the floor. 
1.  Position the Cabinet 
Allow 1 inch between the wall and the rear to assure proper ventilation  
2.  Level Cabinet 
The cabinet should be level side to side and front to back.  Place a carpenter’s level in the interior cabinet floor 
in four places: 
•  The inside floor of the unit near the door.  Level should be parallel to the front of the cabinet. 
•  The inside rear of the unit near the door.  Level should be parallel to the back of the cabinet. 
•  The inside left and right sides.  Level should be parallel to the depth of the cooler.  
3.  Apply Sealant 
•  Draw an outline on the base of the floor 
•  Raise and block the front sides of the cabinet 
•  Apply a bead of NSF approved sealant to the floor half an inch inside of your drawn outline.  The bead 
must be heavy enough to seal the entire cabinet surface when it is set down on the sealant. 
•  Raise and block the rear of the cabinet. 
•  Apply sealant on the floor as outline above. 
•  Examine to see that the cabinet is sealed to the floor around the entire perimeter. 
 
ADJUSTING THE BIN DIVIDERS: 
The factory installed bin dividers can be repositioned as you see fit.  To remove the bin dividers, simply push the divider 
towards the back wall unit until the front of the divider is removed from the positioning holes.  To install, position the 
divider into the desired holes, making sure that the pressure spring is installed properly. 
 
LOADING PRODUCT: 
Pay close attention to the load limit stickers located on the interior walls of the unit.  Do not load product above the load 
limit stickers or above the top cross bar of the bin dividers.  Loading product above the load limit stickers will harm the 
performance of the unit.