6. DISPLAY AND OPERATION SECTIONS 
 
6.9.2 JOG operation 
POINT 
 
When performing JOG operation, turn ON EMG, LSP and LSN. LSP and LSN can 
be set to automatic ON by setting parameter No.PD01 to " C
". 
 
 
JOG operation can be performed when there is no command from the external command device. 
 
(1) Operation 
The servo motor rotates while holding down the "UP" or the "DOWN" button. The servo motor stops rotating 
by releasing the button. The operation condition can be changed using the MR Configurator. The initial 
conditions and setting ranges for operation are listed below. 
 
Item 
Initial setting 
Setting range 
Speed [r/min] 
200 
0 to instantaneous permissible speed 
Acceleration/deceleration time constant [ms] 
1000 
0 to 50000 
 
How to use the buttons is explained below. 
 
Button Description 
"UP" 
Press to start CCW rotation. 
Release to stop. 
"DOWN" 
Press to start CW rotation. 
Release to stop. 
 
If the communication cable is disconnected during JOG operation using the MR Configurator, the servo 
motor decelerates to a stop. 
 
(2) Status display 
Call the status display screen by pressing the "MODE" button in the JOG operation stand-by status. When 
the JOG operation is performed using the “UP” or the “DOWN” button, the servo status appears on the 
display. 
The status display screen shifts to the next screen every time the "MODE" button is pressed. For details of 
the status display, refer to section 5.3. The status display screen returns to the JOG operation stand-by 
screen after one screen cycle. Note that the status display screen cannot be changed by the "UP" or the 
"DOWN" button in the JOG operation mode. 
 
(3) Termination of JOG operation 
To end the JOG operation, turn the power off once or press the "MODE" button to switch to the next 
screen, and then hold down the "SET" button for 2[s] or longer.