Mitsumi electronic MR-J3- A Manual De Usuario

Descargar
Página de 670
 
 
7 -  11 
7. GENERAL GAIN ADJUSTMENT 
 
7.5 Differences between MELSERVO-J2-Super and MELSERVO-J3 in auto tuning 
To meet higher response demands, the MELSERVO-J3 series has been changed in response level setting 
range from the MELSERVO-J2-Super series. The following table lists comparison of the response level setting. 
 
MELSERVO-J2-Super MELSERVO-J3 
Parameter No.2 setting 
Guideline for machine resonance 
frequency [Hz] 
Parameter No.PA09 setting 
Guideline for machine resonance 
frequency [Hz] 
 
 
1 10.0 
2 11.3 
3 12.7 
1 15 
4  14.3 
 
 
5 16.1 
6 18.1 
2 20 
7  20.4 
  8 
23.0 
3 25 
9  25.9 
4 30 
10  29.2 
  11 
32.9 
5 35 
12  37.0 
  13 
41.7 
6 45 
14  47.0 
7 55 
15  52.9 
  16 
59.6 
8 70 
17  67.1 
  18 
75.6 
9 85 
19  85.2 
  20 
95.9 
A 105 
21  108.0 
  22 
121.7 
B 130 
23  137.1 
C 160 
24  154.4 
  25 
173.9 
D 200 
26  195.9 
  27 
220.6 
E 240 
28  248.5 
  29 
279.9 
F 300 
30  315.3 
 
 
31 355.1 
32 400.0 
 
Note that because of a slight difference in gain adjustment pattern, response may not be the same if the 