Mitsumi electronic MR-J3- A Manual De Usuario

Descargar
Página de 670
 
 
12 -  96 
12. OPTIONS AND AUXILIARY EQUIPMENT
 
12.19 EMC filter (recommended) 
For compliance with the EMC directive of the IEC/EN Standard, it is recommended to use the following filter. 
Some EMC filters are large in leakage current. 
 
(1) Combination with the servo amplifier 
 
Servo amplifier 
Recommended filter (Soshin Electric) 
Mass [kg]([lb]) 
Model Leakage 
current 
[mA] 
MR-J3-10A to MR-J3-100A 
MR-J3-10A1 to MR-J3-40A1 
(Note) HF3010A-UN 
3 (6.61) 
MR-J3-250A MR-J3-350A (Note) 
HF3030A-UN 
5.5 
(12.13) 
MR-J3-500A MR-J3-700A (Note) 
HF3040A-UN 
1.5 
6.0 
(13.23) 
MR-J3-11KA to MR-J3-22KA 
(Note) HF3100A-UN 
6.5 
15 (33.07) 
MR-J3-60A4 to MR-J3-100A4 
TF3005C-TX 
5.5 
6(13.23) 
MR-J3-200A4 MR-J3-700A4 TF3020C-TX 
MR-J3-11KA4 TF3030C-TX 
7.5(16.54) 
MR-J3-15KA4 TF3040C-TX 
12.5(27.56) 
MR-J3-22KA4 TF3060C-TX 
Note. A surge protector is separately required to use any of these EMC filters. 
 
(2) Connection example 
NFB
L
1
L
2
L
3
L
11
L
21
Servo amplifier
1
2
3
4
5
6
E
(Note 2)
Surge protector 1
(RAV-781BYZ-2)
(OKAYA Electric Industries Co., Ltd.)
(Note 2)
Surge protector 2
(RAV-781BXZ-4)
(OKAYA Electric Industries Co., Ltd.)
(Note 1)
Power supply
1
2
3
1
2
3
MC
EMC filter
 
Note 1. For 1-phase 200 to 230VAC power supply, connect the power supply to L
1
, L
2
 
and leave L
3
 open. 
            There is no L
3
 for 1-phase 100 to 120VAC power supply. Refer to section 1.3 for 
the power supply specification. 
         2. The example is when a surge protector is connected.