Mitsumi electronic MR-J3- A Manual De Usuario
13 - 14
13. COMMUNICATION FUNCTION
13.4.2 Write commands
(1) Status display (Command [8][1])
Command
Data No.
Description
Setting range
Frame length
[8][1]
[0][0]
Status display data erasure
1EA5
4
(2) Parameters (Command [8][4] [8][5])
Command
Data No.
Description
Setting range
Frame length
[8][4]
[0][1] to [F][F] Write of parameters
Writes the values of the parameters in the
parameter group specified with the command
[8][5] data No.[0][0]. Before writing the values,
therefore, always specify the parameter group
with the command [8][5] data No.[0][0].
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the parameter
number.
parameter group specified with the command
[8][5] data No.[0][0]. Before writing the values,
therefore, always specify the parameter group
with the command [8][5] data No.[0][0].
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the parameter
number.
Depending on the parameter
8
[8][5] [0][0]
Parameter
group
write
0000: Basic setting parameter (No.PA
)
0001: Gain filter parameter (No.PB
)
0002: Extension setting parameter (No.PC
)
0003: I/O setting parameter (No.PD
)
0000 to 0003
4
(3) External I/O signal (Command [9][2])
Command
Data No.
Description
Setting range
Frame length
[9][2]
[6][0]
Communication input device signal
Refer to section 13.5.5
8
(4) Alarm history (Command [8][2])
Command
Data No.
Description
Setting range
Frame length
[8][2]
[2][0]
Alarm history erasure
1EA5
4
(5) Current alarm (Command [8][2])
Command
Data No.
Description
Setting range
Frame length
[8][2] [0][0]
Alarm
erasure
1EA5
4
(6) I/O device prohibition (Command [9][0])
Command
Data No.
Description
Setting range
Frame length
[9][0]
[0][0]
Turns OFF the input device, external analog
input signal or pulse train input, except EMG,
LSP and LSN, independently of the external
ON/OFF status.
input signal or pulse train input, except EMG,
LSP and LSN, independently of the external
ON/OFF status.
1EA5 4
[0][3]
Disables all output devices (DO).
1EA5
4
[1][0]
Cancels the prohibition of the input device,
external analog input signal or pulse train input,
except EMG, LSP and LSN.
external analog input signal or pulse train input,
except EMG, LSP and LSN.
1EA5 4
[1][3]
Cancels the prohibition of the output device.
1EA5
4