15. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW) 
 
15.1.3 Standard specifications 
(1) Converter unit 
 
Converter unit 
Item 
MR-J3-CR  
55K 55K4 
Output 
Rated voltage 
283 to 326VDC 
538 to 678VDC 
Rated current 
[A] 
215.9 
113.8 
Main circuit power 
supply 
Voltage, frequency 
3-phase 200 to 230VAC, 50/60Hz 
3-phase 380 to 480VAC, 50/60Hz 
Rated current 
[A] 
251.1 
132.2 
Permissible voltage 
fluctuation 
3-phase 170 to 253VAC 
3-phase 323 to 528VAC 
Permissible frequency 
fluctuation 
Within 5  
Control power 
supply 
Voltage, frequency 
1-phase 200 to 230VAC, 50/60Hz 
1-phase 380 to 480VAC, 50/60Hz 
Rated current 
[A] 
0.3 
0.2 
Permissible voltage 
fluctuation 
1-phase 170 to 253VAC 
1-phase 323 to 528VAC 
Permissible frequency 
fluctuation 
Within 5  
Power consumption [W] 
45 
Interface power 
supply 
Voltage 24VDC 10  
Power supply capacity 
[A] 
(Note) 0.13 
Rated output 
[kW] 
55 
Regenerative power 
(Using regenerative option) 
One MR-RB139: 1300W 
Three MR-RB137: 3900W 
One MR-RB136-4: 1300W 
Three MR-RB138-4: 3900W 
Protective function 
Regenerative overvoltage shutoff, overload shutoff (electronic thermal protector) 
Regenerative error protection, undervoltage, instantaneous power failure protection 
Compliance to standards 
CE (LVD: IEC/EN 50178, EMC: IEC/EN 61800-3) 
UL (UL 508C) 
Structure 
Force-cooling, open (IP rating: IP00) 
Environmental conditions 
Ambient 
temperature 
In operation 
[ ] 
0 to 55 (non-freezing) 
[ ] 
32 to 131 (non-freezing) 
In storage 
[ ] 
20 to 65 (non-freezing) 
[ ] 
4 to 149 (non-freezing) 
Ambient 
humidity 
In operation 
90 RH or less (non-condensing) 
In storage 
Ambient 
Indoors (no direct sunlight) 
Free from corrosive gas, flammable gas, oil mist, dust and dirt 
Altitude 
Max. 1000m above sea level 
Vibration 5.9 
[m/s
2
] or less at 10 to 55Hz (directions of X, Y and Z axes) 
Mass 
[kg] 25 
[lb] 55.1 
Note. 0.13A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O 
points.