15. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW) 
 
15.4.2 Status display mode 
The servo status during operation is shown on the 3-digit, 7-segment LED display. Press the "UP" or "DOWN" 
button to change display data as desired.  
When the required data is selected, the corresponding symbol is displayed. Press the "SET" button to display 
that data. 
The converter unit display section can show four items of data such as the effective load ratio. 
 
(1) Display examples 
The following table shows the display examples. 
 
Item Status 
Display 
Status 
Ready off 
 
Ready on 
 
Bus voltage 
300 [V] 
 
Effective load ratio 
67 [ ] 
 
Peak load ratio 
95 [ ] 
 
Regenerative load ratio 
90 [ ] 
 
 
(2) Status display list 
The following table lists the converter unit statuses that may be displayed. 
 
Status display 
Symbol 
Unit 
Description 
Indication 
range 
Status 
Ready 
off 
 
 
The ready off is displayed during initialization or alarm occurrence, in the 
forced stop status, or when the bus voltage is not established. 
roF 
Ready 
on 
 
 
The ready on is displayed when the servo was switched on after completion 
of initialization and the servo amplifier is ready to operate. 
ron 
Bus voltage 
The converter unit voltage is displayed. 
0 to 999 
Effective load 
ratio 
 
Continuous effective load torque is displayed. (Note) 
The effective value in the past 15 seconds is displayed relative to the rated 
current of 100 . 
0 to 300 
Peak load ratio 
 
The peak output is displayed. (Note) 
The peak value in the past 15 seconds is displayed relative to the rated 
torque of 100 . 
0 to 400 
Regenerative 
load ratio 
 
The percentage of regenerative power to the permissible regenerative value 
is displayed. 
0 to 300 
Note. Output = converter unit bus voltage output current