15 -  84 
15. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW) 
 
15.9.6 Power factor improving DC reactor 
The input power factor is improved to about 95 . 
 
Converter unit 
Drive unit 
Power factor improving
DC reactor 
Dimension [mm] 
Terminal
screw 
Mass 
[kg (lb)] 
W D  H W1 X 
MR-J3-CR55K 
MR-J3-DU30KA MR-DCL30K 
135 
255 215  80  232  M12 
9.5 
(20.94) 
MR-J3-DU37KA MR-DCL37K 
 MR-J3-DU30KA4 
MR-DCL30K-4 
205 
200 
75 175 
M8 
6.5 
(14.33) 
MR-J3-CR55K4 
MR-J3-DU37KA4 MR-DCL37K-4 
225 
80 
197 
(15.43) 
MR-J3-DU45KA4 MR-DCL45K-4 
240 
212 
7.5 
(16.54) 
 MR-J3-DU55KA4 
MR-DCL55K-4 
260 
215 
232 
9.5 
(20.94) 
 
H o
le
ss
X
D or less
Terminal cover
Terminal screw
Terminal block (M3.5 screw)
For thermal sensor
P
1
P
2
Approx. W1
W or less
Mounting hole
for M8
1.5
1.5