3com WX1200 3CRWX120695A Manual De Usuario
set security acl hit-sample-rate
559
See Also
set security acl
hit-sample-rate
hit-sample-rate
Specifies the time interval, in seconds, at which the packet counter for
each security ACL is sampled for display. The counter counts the number
of packets filtered by the security ACL — or “hits.”
each security ACL is sampled for display. The counter counts the number
of packets filtered by the security ACL — or “hits.”
Syntax —
set security acl hit-sample-rate seconds
seconds
— Number of seconds between samples. A sample rate of 0
(zero) disables the sample process.
Defaults — By default, the hits are not sampled.
Access — Enabled.
History — Introduced in MSS Version 3.0. Syntax changed from
hit-sample-rate seconds to set security acl hit-sample-rate seconds,
to allow the command to be saved in the configuration file.
hit-sample-rate seconds to set security acl hit-sample-rate seconds,
to allow the command to be saved in the configuration file.
Usage — To view counter results for a particular ACL, use the display
security acl info acl-name command. To view the hits for all security
ACLs, use the display security acl hits command.
security acl info acl-name command. To view the hits for all security
ACLs, use the display security acl hits command.