Signature  Series (HP15 model)
TROUBLESHOOTING
BEFORE CALLING FOR SERVICE:
If the unit appears to be malfunctioning, read through NORMAL OPERATION first. If the problem persists, check the TROUBLESHOOTING 
GUIDE.  Locate  the  problem  in  the  guide  and  refer  to  the  cause  and  its  remedy  before  calling  for  service.  The  problem  could  be 
something which can be solved without a service call.
DANGER
NEVER  ATTEMPT  TO  REPAIR  OR  PERFORM  MAINTENANCE  ON  THE  UNIT  UNTIL  THE  MAIN  ELECTRICAL  POWER  HAS  BEEN 
DISCONNECTED!
Problem: No interior light
• 
Is the bulb loose?
• 
Is the bulb burnt out?
Problem: Light stays on when door is closed
• 
Manual ON/OFF light switch is turned ON
• 
Is the door switch making contact with the door?
Problem: Noise during operation
• 
Certain sounds are normal. Soft sounds from the compressor, fan motor and valves will be heard
Problem: Controller display is flashing “P1”
• 
There is a thermostat probe failure
Problem: Controller display is flashing “HA”
• 
The internal compartment temperature has exceeded the high temperature alarm preset value for over 30 minutes.
• 
Check to ensure door is closed
• 
Check door gasket seal
• 
Has warm product been placed in the cabinet?
• 
Is the condenser clean?
• 
In the louvered toe plate obstructed?
• 
Has the surrounding ambient temperature changed dramatically?
• 
Is the interior light ON?
Problem: Controller display is flashing “LA”
• 
The internal compartment temperature has exceeded the low temperature alarm preset value for over 30 minutes
• 
Check to ensure door is closed
• 
Check for gasket seal
• 
Has the surrounding ambiant temperature changed dramatically?
Problem: Controller display is flashing “EE”
• 
The controller has a data or memory failure
Problem: The refrigerated cabinet isn’t running
• 
Is there electrical power to the unit?
• 
Is your home circuit breaker or fuse on?
• 
Is your ON/OFF key pad on?
• 
Is your condenser area clean?