Models BBR/BBS Installation & Operation Manual
Printed in USA 
0213
PrIor To InsTallaTIon
Uncrating and Inspection
Remove  all  crating  material.  Carefully  inspect 
cabinet  for  hidden  damage.  If  damage  is 
discovered, file your claim immediately with the 
transport company. Perlick is not responsible for 
damage in transit.
CAUTION
Do  not  cut  cardboard 
sleeve  covering  the  unit. 
Cutting may result in damage to the exterior 
of the cabinet. Failure to follow this procedure 
may  damage  the  compressor  and  void 
warranty.
1.  Uncrate the unit on flat, level surface. Remove 
the cardboard sleeve by removing the banding 
securing  the  sleeve  to  the  shipping  base. 
Carefully lift the cardboard sleeve up over the 
top of the unit.
2.  Carefully lift unit off the base and onto a hand 
truck  or  dolly.  Make  sure  unit  is  balanced 
on  transporting  device  using  soft,  flexible 
strapping.  Protect  unit  surfaces  with  cloth 
material where strapping contacts unit.
CAUTION
Do not lift unit by drawer, 
shelving or door handles 
or damage to the unit could occur.
WARNING
To  prevent  personal 
i n j u r y,   t w o   p e o p l e 
minimum required to lift the unit. Larger units 
may require additional personnel.
3.  Before moving unit, secure door(s) to unit with 
tape to prevent from opening.
4.  Carefully  move  unit  to  installation  site  and 
place in front of opening.
CAUTION
Finished  flooring  should 
b e   p r o t e c t e d   w i t h 
appropriate  material  to  avoid  damage  from 
moving the unit.
Plumbing
CAUTION
Do not over-tighten drain 
fitting  or  damage  to  the 
threads could occur.
Condensate from the cooling coil is automatically 
evaporated from the condensate pan located in 
the  condensing  unit  housing  on  self-contained 
models.
Each unit is equipped with a floor drain located  
in the right rear corner of the cabinet. The drain 
can  be  plumbed  to  an  external  floor  drain  by 
connecting to the 3/4” NPT thread connection on 
the side, or the 1” NPS thread connection out the 
bottom, of the unit. Both drain ports come plugged 
from the factory and can be removed if needed.
NOTE:  Remote  units  require  evaporator 
condensate to be plumbed to an external drain.
Electrical
The cabinet must be connected to a separately 
fused power source (see Electrical Specification 
Plate affixed to unit) in accordance with National 
and Local electrical codes.
Self-contained Perlick units come equipped with 
a NEMA 5-15P 90° plug with an 8’ cord extending 
beyond  the  rear  of  the  cabinet. The  electrical 
outlet must be flush with, or recessed into, the 
wall surface.
NOTE: Never use an extension cord to extend the 
power cord to the electrical receptacle.
CAUTION
If unit has been laid on its 
back  or  sides,  place  unit 
upright and allow minimum of 24 hours before 
connecting  power.  Failure  to  follow  this 
procedure may damage the compressor and 
void the warranty.
CAUTION
Do not attempt to operate 
the  equipment  on  any 
other  power  source  than  that  listed  on  the 
Electrical Specification Plate attached to the 
unit.
DANGER
ELECTROCUTION HAZARD! 
Electrical  grounding  is 
required. Appliances furnished with a 3-prong 
(grounding) polarized plug are equipped for 
your  protection  against  possible  shock 
hazards.
•  Never remove the round grounding prong 
from the plug.
•  Never use a 2-prong adapter.
•  Never  use  extension  cord  to  connect 
power to the unit.
•  If a 2-prong receptacle is encountered, or 
a longer power cord is required, contact 
a qualified electrician to have it replaced 
in  accordance  with  applicable  electrical 
codes.
DANGER
Failure to comply with these 
electrical  guidelines  may 
result in possible death or serious injury, fire, 
or loss of property.