Heatcraft Refrigeration Products H-IM-82B Manual De Usuario

Descargar
Página de 20
4
1.
O
wner's
O
per
ating
Instr
uc
tions
Some general rules for the evaporator section placement which 
must be followed are:
1. 
Ensure that the structural integrity of the box can  
 
withstand the weight of the top mounted equipment.
2. 
The air pattern must cover the entire room.
3. 
NEVER locate the evaporator section over doors.
4. 
Location of aisles, racks, etc. must be known.
5. 
Never remove or unlock any panel cam-locks to install  
 
top mounted equipment.
The size and shape of the storage will generally determine the type 
and number of units to be used and their location.
Top View
One
System
 
Evaporator
Section
Compressor
Section
Evaporator
Airflow
Multiple units must be spaced 
properly to provide adequate air 
circulation.
Top View
Two
Systems
W
Min.
W
Min.
2 x Width
Min.
Evaporator
Section
Compressor
Section
Evaporator
Section
Compressor
Section
W = Unit Width
Evaporator
Airflow
Evaporator
Airflow
NOTE:  Always avoid placement of
units directly above doors
and door openings.
Recommended Unit Placement For PTT Models