• Standard boot order: Standard boot order is supported for all Cisco UCS servers, and enables top-level
boot order choices. You can add a local device, such as local disk, CD-ROM, or floppy, or you can add
SAN, LAN, or iSCSI boot.
• Enhanced boot order: Enhanced boot order allows you greater control over the boot devices that you
select for your boot policy. Enhanced boot order is supported for all Cisco UCS B-Series M3 Blade
Servers and Cisco UCS C-Series M3 Rack Servers at release 2.2(1b) or greater.
Enhanced boot order provides you the following additional second-level boot order choices:
• Add Local LUN - Enables boot from local hard disk.
• Add SD Card - Enables boot from SD Card.
• Add Internal USB - Enables boot from Internal USB.
• Add External USB - Enables boot from External USB.
• Add Local CD/DVD - Enables boot from local CD/DVD drive.
• Add Remote CD/DVD - Enables boot from KVM mapped ISO images.
• Add Local Floppy - Enables boot from local floppy drive.
• Add Remote Floppy - Enables boot from KVM mapped image files.
• Add Remote Virtual Drive - Enables boot from remote virtual drive that is accessible to the server.
• Add LAN, SAN or iSCSI Boot - Enables you to select a specific vNIC or vHBA from which to boot.
Local Disk CD/DVD ROM boot are available for backward compatibility.
Note
• If a boot policy with enhanced boot order is applied to Cisco UCS M1 and M2 blade and rack servers,
or to Cisco UCS M3 blade and rack servers with a release prior to Release 2.2(1b) installed, the
association fails with configuration errors.
• You must enable USB for Virtual Media. If you modify the BIOS settings, that in turn affects the
Virtual media. The following USB BIOS default settings are recommended for best performance:
Make Device Non Bootable - set to disabled
USB Idle Power Optimizing Setting - set to high-performance
UEFI Boot Mode
Unified Extensible Firmware Interface (UEFI) is a specification that defines a software interface between an
operating system and platform firmware. Cisco UCS Manager uses UEFI to replace the BIOS firmware
interfaces. This allows the BIOS to run in UEFI mode while still providing legacy support.
You can choose either legacy or UEFI boot mode when you create a boot policy. Legacy boot mode is supported
for all Cisco UCS servers. UEFI boot mode is supported only on M3 and M4 servers, and allows you to enable
UEFI secure boot mode.
The following limitations apply to the UEFI boot mode:
Cisco UCS Central Software User Manual, Release 1.2    
243
Server Policies
UEFI Boot Mode