Product Characteristics 
 
4.5 SCALANCE X005 Power Supply 
4.5  SCALANCE X005 Power Supply 
Power Supply 
The power supply is connected using a 2-pin plug-in terminal block. The power supply is 
connected over a high resistance with the enclosure to allow an ungrounded setup. The 
power supply is non-floating. 
 
 
Figure 4-3 
Power supply 
Figure 4-4 
Connector pinout 
Pin number  Pinout 
Pin 1 
M  (Mass) 
Pin 2  
L+ (+18 - 32V DC) 
 
 
Warning 
The SCALANCE X005 device is designed for operation with safety extra-low voltage. This 
means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ 
VDE0805  can be connected to the power supply terminals. 
The power supply unit to supply SCALANCE X005 must comply with NEC Class 2 (voltage 
range 18 - 32 V, current requirement 350 mA). 
Never connect SCALANCE X005 to AC voltage.  
Never connect SCALANCE X005 to DC voltage higher than 32 V DC. 
4.6  SCALANCE X005 LEDs 
Power indicator (green LED) 
The status of the power supply is indicated by a green LED: 
 
Status 
Meaning 
Lit green 
Power supply is connected. 
Not lit 
Power supply is not connected or <14 V 
Industrial Ethernet SCALANCE X005 
Commissioning Manual, A2B00051528A 
4-5