CyberPower Systems PR750LCDRM1U Prospecto

Descargar
Página de 2
 
 
 
 
 
Smart App Sinewave Series 
PR750LCDRM1U/PR1000LCDRM1U 
User’s Manual 
 
                                                                K01-0000059-04
 
 
This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read 
and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, 
or operate. 
CAUTION!    The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection. DO NOT plug the UPS into an 
outlet that is not grounded.    If you need to de-energize this equipment, turn off and unplug the UPS.   
CAUTION!    DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!  CyberPower
 
Systems does not sell products for life support or 
medical applications. DO NOT use in any circumstance that would affect operation or safety of any life support equipment, with any medical 
applications, or patient care. 
CAUTION!    The battery can energize hazardous live parts inside even when the AC input power is disconnected. 
CAUTION!  For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible. 
CAUTION!  To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive 
contaminants. (Please see specifications for acceptable temperature and humidity range). 
CAUTION!    To reduce the risk of electric shock, do not remove the cover, except to service the battery. There are no serviceable parts inside, 
except for the battery. 
CAUTION!  To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a 
computer component. 
CAUTION!    DO NOT USE WITH OR NEAR AQUARIUMS!    To reduce the risk of fire, do not use with or near aquariums.    Condensation from 
the aquarium can come in contact with metal electrical contacts and cause the machine to short out. 
CAUTION!    DO NOT USE WITH LASER PRINTERS! The power demands of laser printers are too large for a UPS. 
 
 
 
UNPACKING 
Inspect the UPS upon receipt. The box should contain the following. 
(1) UPS Unit; (1) User's Manual for UPS; (2) Rack mount Brackets; (1) Emergency Power Off Cable (gray) (1) PowerPanel
®
 Business Edition 
Software CD; (1) Serial Interface Cable (DB-9); (1) USB A+B type cable; (1) Warranty Registration Card. 
 
OVERVIEW 
The PR750LCDRM1U/PR1000LCDRM1U provides automatic voltage regulation for inconsistent utility power. 
The PR750LCDRM1U/PR1000LCDRM1U features 1874 Joules of surge protection, and provides battery 
backup during power outages. The PR750LCDRM1U/PR1000LCDRM1U ensures consistent power to your 
computer system and its included software will automatically save your open files and shutdown your 
computer system during a utility power loss.
 
 
AUTOMATIC VOLTAGE REGULATOR(AVR)
 
The PR750LCDRM1U/PR1000LCDRM1U    stabilizes inconsistent utility power. The incoming utility power may be damaging to important data 
and hardware, but with Automatic Voltage Regulation, the computer will not experience damaging voltage levels. An Automatic Voltage Regulator 
automatically increases low or decreases high voltage to a consistent, computer safe 110v/120v. The unit powerful sealed lead-acid batteries will 
provide power only if the incoming voltage drops below 80v or increases above 150v. 
 
SYSTEM BLOCK DIAGRAM 
 
 
 
 
 
 
 
 
 
 
 
 
 
HARDWARE INSTALLATION GUIDE 
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least four hours 
is recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss may occur 
during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit 
will charge in both the on and off position. 
2. If you will use the software, connect the serial interface cable to the serial port on the UPS and the computer. If 
you would like to use USB cable, please connect the USB cable on the UPS then connect the USB cable to your 
computer. 
3. With the UPS unit off and unplugged, connect your computer, monitor, and any externally powered data 
storage device (Hard drive, Tape drive, etc.) into the battery power supplied outlets.  DO NOT plug a laser 
printer, copier, space heater, vacuum, paper shredder or other large electrical device into the UPS. The power 
demands of these devices will overload and possibly damage the unit. 
4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet).    Make sure the wall branch outlet is 
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air 
conditioner, refrigerator, copier, etc.). Avoid using extension cords. 
5. Depress the power switch to turn the unit on. The power on indicator light will illuminate. If an overload is 
detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and 
unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the 
circuit breaker is depressed and then turn the UPS on. 
6. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will 
automatically recharge. 
7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
8. To store your UPS for an extended period, cover it and store with the battery fully charged.    Recharge the 
battery every three months to ensure battery life. 
9. Professional Rack Mount UPS provides one serial port, one dry contact and one USB port to allow connection 
and communication between the UPS and computers or equipment. This allows the simultaneous shutdown of 
two computer systems. Serial port II produces the basic information for equipment that can utilize a dry contact 
ups. The Primary computers (with PowerPanel® Business Edition installed) are the computers that you will use 
to control the UPS and make any changes to the operation of the UPS. When there is a power failure, the 
computer which connects to Primary port will start to shutdown after a user controlled delay. PowerPanel® 
Business Edition will save and close any open files prior to shutting the system down. 
10. EPO (Emergency Power Off) Port: 
The feature is for the application to enable emergency power shutdown. Use the gray cable provided to connect 
the UPS to a normally closed or normally open contact switch according to the circuit diagram. EPO function is 
provided in the UPS. EPO remote switch which is a Push-Back button installed computer room outside by a 
phone line, and not connected any other equipment. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FRONT / REAR PANEL DESCRIPTION 
1. Power Switch 
Master on/off switch for equipment connected to the UPS. 
2. Power On Indicator 
Indicates the power is on.   
3. LCD Module Display 
LCD shows all the UPS information with icons and messages. 
4. LCD Display Toggle Button 
The button can be used to toggle between different data displays 
on the LCD.   
5Battery Backup Protected Outlets 
Provides eight battery powered, surge protected and AVR outlets 
for connected equipment and ensures temporary uninterrupted 
operation of connected equipment during a power failure. 
Critical /Non-critical   
When the UPS is overloaded, the circuit breakers will be tripped 
to interrupt the power supply to the uncritical outlets while 
continuing to supply the critical outlets. As well, as the battery 
capacity depletes under the threshold value, the uncritical outlets 
will  be shut down and provide energy for critical outlets. The 
threshold can be determined and set by users. Non-critical 
outlets can also be turned on/off manually through the software 
package provided. 
6. Input Power Cord 
Heavy-duty, extra long power cord. 
7
. Input Circuit Breaker 
Resettable circuit breakers provide Input optimal overload 
Protection. 
 
 
 
 
Contact your dealer, or email tech@cpsww.com. Refer to replacement battery pack number RBP422 for PR750LCDRM1U/PR1000LCDRM1U
Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery.  Service the battery under the supervision of 
personnel knowledgeable of batteries and their precautions. Servicing the battery should only be performed by trained personnel. 
Replacement of batteries located in an OPERATOR ACCESS AREA. 
CAUTION!    When replacing batteries, replace with the same number of the following battery: HR9-6(BB) for PR750LCDRM1U/ 
PR1000LCDRM1U.   
CAUTION!  Risk of Energy Hazard, 6V, maximum 9 Ampere-hour (HR9-6) batteries. Before replacing batteries, remove conductive jewelry such 
as chains, wrist watches, and rings. High energy through conductive materials could cause severe burns. 
CAUTION!    Risk of battery explosion, if battery is replaced by an incorrect type. Dispose of used battery according to the instructions. 
CAUTION!    To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in 
accordance with the National Electric Code, ANSI/NFPA 70. 
CAUTION!    Use only the specified type of battery. See your dealer for replacement batteries. 
CAUTION!  The battery may present the risk of electrical shock. Do not dispose of batteries in a fire, as they may explode. Follow all local 
ordinances regarding proper disposal of batteries. 
CAUTION!    Do not open or mutilate the batteries. Release electrolyte is harmful to the skin and eyes and may be toxic. 
CAUTION!  A battery can present a high risk of short circuit current and electrical shock. 
 
Take the following precautions before replacing the battery

1. Remove all watches, rings or other metal objects. 
2. Only use tools with insulated handles. 
3. Do not lay tools or metal parts on top of battery or any terminals. 
4. Wear rubber gloves and boots. 
5. Determine if the battery is inadvertently grounded.    If inadvertently grounded, remove source of ground. CONTACT WITH A GROUNDED 
BATTERY CAN RESULT IN ELECTRICAL SHOCK! 
The likelihood of such shock will be reduced if such grounds are removed during installation 
and maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit) 
 
BATTERY REPLACMENT PROCEDURE: 
 
 
 
 
 
 
 
 
.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Line mode 
UPS Status Display 
Capacity Display 
Digital Value Display 
 
Select SW 
Press 
  
  Load 
Cap 
Battery
Cap 
Input 
Voltage
Output 
Voltage
Run 
Time 
% of 
Load 
% of 
Battery 
Initial  V X -- X 
 
V  V 
 
 
 
 
1
st
  V X -- X 
 
V   
 
 
 
2
nd
  V X -- X  V   
 
 
 
 
3
rd
  V X -- X 
 
V   
 
 
 
4
th
  V X -- X 
 
 
  V 
 
 
 
5
th
(return) 
V X -- X 
 
V  V   
 
 
 
(overload) 
V X -- V  --  --  --  --  --  V  -- 
 
Battery Mode 
UPS Status Display 
Capacity Display 
Digital Value Display 
 
Select SW 
Press 
     Load 
Cap 
Battery 
Cap 
Input 
Voltage
Output 
Voltage
Run 
Time 
% of 
Load 
% of 
Battery 
Initial X 
-- 
 V 
V  
 
 
 
1
st
 X 
-- 
 
 
 
 
 
2
nd
 X 
-- 
 
 
 
 
 
3
rd
 X 
-- 
 
 
 
 
 
4
th
  X 
-- 
    
 
 
5
th
(return) X V 
-- 
X   V  V      
 
Press>4sec 
(sound disable) 
X  V V X   
-- 
-- 
--  -- -- 
-- 
Press>4sec 
again(sound enable) 
X V 
-- -- -- -- 
-- 
-- 
-- 
overload 
X  V -- V   
-- 
-- 
--  -- V 
-- 
“V” illuminated , “X” Not illuminated, “— “ either 
IMPORTANT SAFETY WARNINGS
INSTALLING YOUR UPS SYSTEM
1. Remove the right side front panel
2. Remove the two retaining screws of 
the cable protection cover then remove 
the cover. 
3. Disconnect the black and red cable.
 
4. Remove the one 
retaining screws 
5. Charge a new battery pack. 
Assemble the       screws cover 
cable and front panel in the reverse 
sequence of above steps. Recharge 
the unit for4-8 hours to ensure the 
UPS performs expected runtime
 
LCD STATUS DEFINITION
BATTERY REPLACEMENT
8USB port                                                                                                     
USB communication port for management software. 
9. Serial Port                             
Serial port allows connection and communication between the UPS and the 
computer. 
10. SNMP/HTTP Network slot 
Remove the cover panel to install optional RMCARD that allows remote 
monitoring and control your UPS on networks. 
11. Site Wire Fault Indicator 
This LED will illuminate to warn the user that a wiring problem exists within 
the AC receptacle, such as a bad ground, missing ground or reversed 
wiring. If illuminated, disconnect all equipment and contact an electrician to 
ensure outlet is properly wired. 
12. EPO (Emergency Power Off) port 
The interface can be used to connect to switches for emergency power off. 
BASIC OPERATION
When you first receive the 
unit, plug in the unit to fully 
charge the battery. 
Unplug the unit and turn Power 
Off when first connecting your 
computer and peripherals.