P R O G R A M M I N G  
!RFID LEDFLSH  
Function Controls 
the 
transmission of a ‘Success’ or ‘Failure’ 
indication to the LED display  during and at the 
very end of any CPL-RFID command’s execution.  
Explicit Form 
!RFID LEDFLSH ON/OFF/ACCUM 
Parameters 
ON 
Flashes LED (Green for Success) or (Red 
for Failure)  after any CPL-RFID 
command completion 
 
OFF 
Does NOT flash any LED after CPL-
RFID command  completions. The LED 
normally remains OFF  during a label-
format execution until the printer is 
ready  for the next label or command 
where LED is set Green 
 
ACCUM 
Does NOT flash any LED until after the 
entire label- format has completed 
execution. If all CPL- RFID commands 
completed successfully, the LED is 
flashed GREEN and OFF three times.  
If any CPL-RFID command failed, the 
LED is flashed RED and OFF three 
times. 
Response 
No specific response 
Command Type 
RFID Setup/Debug Command 
Example To 
Printer: 
!RFID LEDFLSH OFF 
NOTE: All CPL-RFID Configuration-Setup Commands 
are processed outside the context of a standard CPL 
Label-Format (i.e. CPL beginning with a header-line ‘! 0 
100 nnn 1’ and ending with ‘END’). Attempts to use 
CPL-RFID Configuration-Setup Commands within a 
Label-Format result are ignored without indication. 
 
Copyright © 2004, Cognitive. 