Chapter 6: DH emulation
144
A776 (B780) Programming Guide 
 
A776-PG00001 C 12/09
Configure Scan Options
Hexadecimal:   1D C6 m n
Parameters:  
m
n
Description
0
-
Configure Imager default settings.  Parameter n is ignored.
1
0
Disable auto eject on top scan jam (default).
1
1
Enable auto eject on top scan jam.
2
n
Set maximum tag storage memory to n Kbytes.  Default 4K.  Range 2K to 64K.  Out of range 
parameter defaults to 4K.
Return:  None 
Description: Configures scan options.  Parameter m>2 reserved for future options  This setting is retained across 
power cycles.
Configure Max Scan Width & Height
Hexadecimal:   1D C7 wL wH lenL lenH
Parameters: wL wH is the maximum width of a scan in pixels (<= physical maximum 832); lenL lenH is the maximum 
length in pixels (<= 2284 ~ 11.25”). The width should be values evenly divisible by 4 value will be truncated by zeroing 
out the lowest-most 2 bits.
Return:  None
Description: This sets the maximum values for all scanned documents to within ½ mm (4 pixels). As the imager must 
be prepared for a maximum size, this allows the firmware to use optimum buffers and thus provide for retaining more 
image slots in a circular buffer arrangement.
This setting is retained across power cycles.
Transmit Printer Type (Extended Existing Command)
Hexadecimal:   1D 49 02
Parameters: None
Return:  M  a single byte, as specified in existing commands, with its undefined bit #5 now used to indicate imager 
installed. 0= not present (existing definition), 1= imager present (new)
Description: This is an additional definition that uses a previously undefined bit to tell applications whether or not an 